﻿document.write('<TABLE cellSpacing=0 cellPadding=0 width="100%" summary=layout border=0>  <TBODY>  <TR>    <TD vAlign=top><H2 class=headerGamma>机型</H2><DIV class="tabularCellB width100pct lineHeight25"       style="MARGIN-TOP: -5px">&raquo; <A       href="/other/procurve/cn/zh/network/products/switches/HP_ProCurve_2520_Switch_Series/overview.htm#J9137A">HP ProCurve 2520-8-PoE 交换机 (J9137A)</A></DIV><DIV class="tabularCellGrayB width100pct lineHeight25">&raquo; <A       href="/other/procurve/cn/zh/network/products/switches/HP_ProCurve_2520_Switch_Series/overview.htm#J9138A">HP ProCurve 2520-24-PoE 交换机 (J9138A)</A></DIV><DIV class="tabularCellB width100pct lineHeight25">&raquo; <A       href="/other/procurve/cn/zh/network/products/switches/HP_ProCurve_2520_Switch_Series/overview.htm#J9298A">HP ProCurve 2520G-8-PoE 交换机 (J9298A)</A></DIV><DIV class="tabularCellGrayB width100pct lineHeight25">&raquo; <A       href="/other/procurve/cn/zh/network/products/switches/HP_ProCurve_2520_Switch_Series/overview.htm#J9299A">HP ProCurve 2520G-24-PoE 交换机 (J9299A)</A></DIV></TD></TR></TBODY></TABLE><DIV class=topSpace><TABLE cellSpacing=0 cellPadding=0 width="100%" summary=layout border=0>  <TBODY>  <TR>    <TD vAlign=top><H2 class=headerGamma>所有机型的标准规格</H2><DIV class="tabularCellB width100pct lineHeight25"       style="MARGIN-TOP: -5px">&raquo; <A       href="/other/procurve/cn/zh/network/products/switches/HP_ProCurve_2520_Switch_Series/overview.htm#emission">排放</A></DIV><DIV class="tabularCellGrayB width100pct lineHeight25">&raquo; <A       href="/other/procurve/cn/zh/network/products/switches/HP_ProCurve_2520_Switch_Series/overview.htm#immunity">抗干扰性</A></DIV><DIV class="tabularCellB width100pct lineHeight25">&raquo; <A       href="/other/procurve/cn/zh/network/products/switches/HP_ProCurve_2520_Switch_Series/overview.htm#management">管理</A></DIV><DIV class="tabularCellGrayB width100pct lineHeight25">&raquo; <A       href="/other/procurve/cn/zh/network/products/switches/HP_ProCurve_2520_Switch_Series/overview.htm#stadProc">标准和协议</A></DIV><DIV class="tabularCellB width100pct lineHeight25">&raquo; <A       href="/other/procurve/cn/zh/network/products/switches/HP_ProCurve_2520_Switch_Series/overview.htm#notes">备注</A></DIV></TD></TR></TBODY></TABLE></DIV><DIV class=topSpace><H3 class=headerBetaBevel><A name=differences></A>机型规格</H3></DIV><DIV><TABLE cellSpacing=1 cellPadding=4 width="100%" bgColor=#cccccc border=0>  <TBODY>  <TR class=theme>    <TH class="small themebody" vAlign=top align=left></TH><TH class="small themebody" vAlign=top scope=col align=left><A       name=J9137A></A>HP ProCurve 2520-8-PoE 交换机<BR>(J9137A)</TH><TH class="small themebody" vAlign=top scope=col align=left><A       name=J9138A></A>HP ProCurve 2520-24-PoE 交换机<BR>(J9138A)</TH><TH class="small themebody" vAlign=top scope=col align=left><A       name=J9298A></A>HP ProCurve 2520G-8-PoE 交换机<BR>(J9298A)</TH></TR>  <TR vAlign=top bgColor=#666666><TD class="small bold colorFFFFFF" scope=col colSpan=4>端口</TD></TR>  <TR vAlign=top bgColor=#e7e7e7>    <TD class="small bold" scope=row></TD><TD class=small>8 个 RJ-45 自适应 10/100 PoE 端口 (IEEE 802.3 Type 10Base-T、IEEE 802.3u Type 100Base-TX、IEEE 802.3af PoE)<BR><BR>介质类型：Auto-MDIX<BR><BR>双工：半双工或全双工<BR><BR>2 个双功能定制端口<BR><BR>每个端口均可用作 RJ-45 10/100/1000 端口（IEEE 802.3 Type 10Base-T、IEEE 802.3u Type 100Base-TX、IEEE 802.3ab 1000Base-T 千兆以太网）或用作 SFP 插槽（用于 SFP 收发器）<BR><BR>1 个 RJ-45 串行控制台端口<BR><BR></TD><TD class=small>24 个 RJ-45 自适应 10/100 PoE 端口 (IEEE 802.3 Type 10Base-T、IEEE 802.3u Type 100Base-TX、IEEE 802.3af PoE)<BR><BR>介质类型：Auto-MDIX<BR><BR>双工：半双工或全双工<BR><BR>2 个 RJ-45 自适应 10/100/1000 端口（IEEE 802.3 Type 10Base-T、IEEE 802.3u Type 100Base-TX、IEEE 802.3ab Type 1000Base-T）<BR><BR>介质类型：Auto-MDIX<BR><BR>双工：10Base-T/100Base-TX：半双工或全双工；1000Base-T：仅全双工<BR><BR>2 个双功能定制端口<BR><BR>每个端口均可用作 RJ-45 10/100/1000 端口（IEEE 802.3 Type 10Base-T、IEEE 802.3u Type 100Base-TX、IEEE 802.3ab 1000Base-T 千兆以太网）或用作 SFP 插槽（用于 SFP 收发器）<BR><BR>1 个 RJ-45 串行控制台端口<BR><BR></TD><TD class=small>8 个 RJ-45 自适应 10/100 PoE 端口 (IEEE 802.3 Type 10Base-T、IEEE 802.3u Type 100Base-TX、IEEE 802.3af PoE)<BR><BR>介质类型：Auto-MDIX<BR><BR>双工：10Base-T/100Base-TX：半双工或全双工；1000Base-T：仅全双工<BR><BR>2 个双功能定制端口<BR><BR>每个端口均可用作 RJ-45 10/100/1000 端口（IEEE 802.3 Type 10Base-T、IEEE 802.3u Type 100Base-TX、IEEE 802.3ab 1000Base-T 千兆以太网）或用作 SFP 插槽（用于 SFP 收发器）<BR><BR>1 个 RJ-45 串行控制台端口<BR><BR></TD></TR>  <TR vAlign=top bgColor=#666666><TD class="small bold colorFFFFFF" scope=col colSpan=4>物理特性</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>外形尺寸</TD><TD class=small>15.95（长）x 25.4（宽）x 4.45（高）厘米（6.28 x 10 x 1.75 英寸） (1U 高)</TD><TD class=small>24.61（长）x 44.3（宽）x 4.45（高）厘米（9.69 x 17.44 x 1.75 英寸 ）(1U 高)</TD><TD class=small>15.95（长）x 25.4（宽）x 4.45（高）厘米（6.28 x 10 x 1.75 英寸） (1U 高)</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>重量	</TD><TD class=small>1.64 千克（3.62 磅），包括电源适配器和电源线</TD><TD class=small>3.22 千克（7.1 磅）</TD><TD class=small>1.66 千克（3.66 磅），包括电源适配器和电源线</TD></TR>  <TR vAlign=top bgColor=#666666><TD class="small bold colorFFFFFF" scope=col colSpan=4>内存及处理器</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>处理器</TD><TD class=small>266 MHz 时 Freescale PowerPC 8313、32MB 闪存、128MB DDR2 SDRAM；数据包缓冲区大小：384KB 动态分配</TD><TD class=small>266 MHz 时 Freescale PowerPC 8313、32MB 闪存、128MB DDR2 SDRAM；数据包缓冲区大小：384KB 动态分配</TD><TD class=small>266 MHz 时 Freescale PowerPC 8313、32MB 闪存、128MB DDR2 SDRAM；数据包缓冲区大小：512KB 动态分配</TD></TR>  <TR vAlign=top bgColor=#666666><TD class="small bold colorFFFFFF" scope=col colSpan=4>安装</TD></TR>  <TR vAlign=top bgColor=#e7e7e7>    <TD class="small bold" scope=row></TD><TD class=small>安装在一个标准 EIA 19 英寸 Telco 机架或设备机柜中（可使用机架安装套件）；限水平表面安装、壁挂安装<BR></TD><TD class=small>安装在一个标准 EIA 19 英寸 Telco 机架或设备机柜中（可使用机架安装套件）；限水平表面安装、壁挂安装<BR></TD><TD class=small>安装在一个标准 EIA 19 英寸 Telco 机架或设备机柜中（可使用机架安装套件）；限水平表面安装、壁挂安装<BR></TD></TR>  <TR vAlign=top bgColor=#666666><TD class="small bold colorFFFFFF" scope=col colSpan=4>性能</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>100Mb 延迟</TD><TD class=small>&lt; 1.9 &micro;s（LIFO 64 字节数据包）</TD><TD class=small>&lt; 1.9 &micro;s（LIFO 64 字节数据包）</TD><TD class=small>&lt; 5.3 &micro;s（LIFO 64 字节数据包）</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>1000Mb 延迟</TD><TD class=small>&lt; 1.5 &micro;s（LIFO 64 字节数据包）</TD><TD class=small>&lt; 1.5 &micro;s（LIFO 64 字节数据包）</TD><TD class=small>&lt; 2.7 &micro;s（LIFO 64 字节数据包）</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>吞吐率</TD><TD class=small>4.1 mpps</TD><TD class=small>6.2 mpps</TD><TD class=small>14.8 mpps</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>交换容量</TD><TD class=small>5.6 Gbps</TD><TD class=small>12.8 Gbps</TD><TD class=small>20 Gbps</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>MAC 地址表大小</TD><TD class=small>8,000 个条目</TD><TD class=small>8,000 个条目</TD><TD class=small>8,000 个条目</TD></TR>  <TR vAlign=top bgColor=#666666><TD class="small bold colorFFFFFF" scope=col colSpan=4>工作环境</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>工作温度</TD><TD class=small>0&ordm;C 到 45&ordm;C（32&ordm;F 到 113&ordm;F ）</TD><TD class=small>0&ordm;C 到 45&ordm;C（32&ordm;F 到 113&ordm;F ）</TD><TD class=small>0&ordm;C 到 45&ordm;C（32&ordm;F 到 113&ordm;F ）</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>工作相对湿度</TD><TD class=small>40&ordm;C (104&ordm;F) 时 15% 到 95%，无凝结</TD><TD class=small>40&ordm;C (104&ordm;F) 时 15% 到 95%，无凝结</TD><TD class=small>40&ordm;C (104&ordm;F) 时 15% 到 95%，无凝结</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>非工作/存放温度</TD><TD class=small>-40&ordm;C 到 70&ordm;C（-40&ordm;F 到 158&ordm;F ）</TD><TD class=small>-40&ordm;C 到 70&ordm;C（-40&ordm;F 到 158&ordm;F ）</TD><TD class=small>-40&ordm;C 到 70&ordm;C（-40&ordm;F 到 158&ordm;F ）</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>非工作/存放相对湿度</TD><TD class=small>65&ordm;C (149&ordm;F) 时 15% 到 95%，无凝结</TD><TD class=small>65&ordm;C (149&ordm;F) 时 15% 到 95%，无凝结</TD><TD class=small>65&ordm;C (149&ordm;F) 时 15% 到 95%，无凝结</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>海拔</TD><TD class=small>高达 3 千米（10,000 英尺）</TD><TD class=small>高达 3 千米（10,000 英尺）</TD><TD class=small>高达 3 千米（10,000 英尺）</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>噪音</TD><TD class=small>声能：0 dB；声压：0 dB</TD><TD class=small>声能：27.9 dB；声压：36.0 dB；根据 ISO 7779，DIN 45635T.19</TD><TD class=small>声能：0 dB；声压：0 dB</TD></TR>  <TR vAlign=top bgColor=#666666><TD class="small bold colorFFFFFF" scope=col colSpan=4>电气特性</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>说明</TD><TD class=small>只使用本产品附带的外置电源适配器模块（5070-6082、PA1 交流适配器）</TD>    <TD class=small></TD><TD class=small>只使用本产品附带的外置电源适配器模块（5070-6082、PA1 交流适配器）</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>最大散热量</TD><TD class=small>87 BTU/小时（91.79 kJ/小时)</TD><TD class=small>208 BTU/小时（219.44 kJ/小时)</TD><TD class=small>89 BTU/小时（93.9 kJ/小时)</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>电压</TD><TD class=small>100-240 伏交流电</TD><TD class=small>100 -127 / 200-240 伏交流电</TD><TD class=small>100-240 伏交流电</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>电流</TD><TD class=small>1.5 安</TD><TD class=small>3.3 / 1.6 安</TD><TD class=small>1.5 安</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>待机功耗</TD><TD class=small>9.4 瓦</TD><TD class=small>21.6 瓦</TD><TD class=small>9.3 瓦</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>最大额定功率</TD><TD class=small>85.5 瓦</TD><TD class=small>257 瓦</TD><TD class=small>86.2 瓦</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>PoE 电源</TD><TD class=small>67 瓦</TD><TD class=small>195 瓦</TD><TD class=small>67 瓦</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>频率</TD><TD class=small>50 / 60 赫兹</TD><TD class=small>50/60 赫兹</TD><TD class=small>50/60 赫兹</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>备注</TD><TD class=small>待机功耗是设备没有连接端口时的实际功耗。<BR>规划完全加载 PoE（如需要）、100% 流量、全部端口插入以及使用全部模块的基础架构时，最大额定功率和最大散热量是最坏情况下的最大理论值。<BR>PoE 功率是所有 PoE 端口可用的总功率预算。<BR>待机功耗是设备没有连接端口时的实际功耗。规划完全加载 PoE、100% 流量、全部端口插入以及使用全部模块的基础架构时，最大额定功率和最大散热量是最坏情况下的最大理论值。</TD><TD class=small>待机功耗是设备没有连接端口时的实际功耗。<BR>规划完全加载 PoE（如需要）、100% 流量、全部端口插入以及使用全部模块的基础架构时，最大额定功率和最大散热量是最坏情况下的最大理论值。<BR>PoE 功率是所有 PoE 端口可用的总功率预算。<BR>待机功耗是设备没有连接端口时的实际功耗。规划完全加载 PoE、100% 流量、全部端口插入以及使用全部模块的基础架构时，最大额定功率和最大散热量是最坏情况下的最大理论值。</TD><TD class=small>待机功耗是设备没有连接端口时的实际功耗。<BR>规划完全加载 PoE（如需要）、100% 流量、全部端口插入以及使用全部模块的基础架构时，最大额定功率和最大散热量是最坏情况下的最大理论值。<BR>PoE 功率是所有 PoE 端口可用的总功率预算。<BR>待机功耗是设备没有连接端口时的实际功耗。规划完全加载 PoE、100% 流量、全部端口插入以及使用全部模块的基础架构时，最大额定功率和最大散热量是最坏情况下的最大理论值。</TD></TR>  <TR vAlign=top bgColor=#666666><TD class="small bold colorFFFFFF" scope=col colSpan=4>安全性</TD></TR>  <TR vAlign=top bgColor=#e7e7e7>    <TD class="small bold" scope=row></TD><TD class=small>cUL (CSA 22.2 No. 60950)<BR>CE 标记<BR>UL 60950-1<BR>UL 列出<BR>CAN/CSA 22.2 No. 60950<BR>EN 60825<BR>AS/NZS 60950<BR>IEC 60950-1<BR>EN 60950-1<BR></TD><TD class=small>cUL (CSA 22.2 No. 60950)<BR>CE 标记<BR>UL 60950-1<BR>UL 列出<BR>CAN/CSA 22.2 No. 60950<BR>EN 60825<BR>AS/NZS 60950<BR>IEC 60950-1<BR>EN 60950-1<BR></TD><TD class=small>cUL (CSA 22.2 No. 60950)<BR>CE 标记<BR>UL 60950-1<BR>UL 列出<BR>CAN/CSA 22.2 No. 60950<BR>EN 60825<BR>AS/NZS 60950<BR>IEC 60950-1<BR>EN 60950-1<BR></TD></TR>  <TR vAlign=top bgColor=#666666><TD class="small bold colorFFFFFF" scope=col colSpan=4>备注</TD></TR>  <TR vAlign=top bgColor=#e7e7e7>    <TD class="small bold" scope=row></TD><TD class=small>此产品使用 mini-GBIC 时需&ldquo;B&rdquo;版（产品编号以字母&ldquo;B&rdquo;或更靠后的字母结尾，例如 J4858B、J4859C）或更高版本的 mini-GBIC。<BR><BR></TD><TD class=small>此产品使用 mini-GBIC 时需&ldquo;B&rdquo;版（产品编号以字母&ldquo;B&rdquo;或更靠后的字母结尾，例如 J4858B、J4859C）或更高版本的 mini-GBIC。<BR><BR></TD><TD class=small>此产品使用 mini-GBIC 时需&ldquo;B&rdquo;版（产品编号以字母&ldquo;B&rdquo;或更靠后的字母结尾，例如 J4858B、J4859C）或更高版本的 mini-GBIC。<BR><BR></TD></TR></TBODY></TABLE></DIV><DIV class=topSpace><UL class=linksUnit style="TEXT-ALIGN: right"><LI>&raquo;<A   href="/other/procurve/cn/zh/network/products/switches/HP_ProCurve_2520_Switch_Series/overview.htm#tabs">返回页首</A></LI></UL></DIV><DIV class=topSpace><TABLE cellSpacing=1 cellPadding=4 width="100%" bgColor=#cccccc border=0>  <TBODY>  <TR class=theme>    <TH class="small themebody" vAlign=top align=left></TH><TH class="small themebody" vAlign=top scope=col align=left><A       name=J9299A></A>HP ProCurve 2520G-24-PoE 交换机<BR>(J9299A)</TH></TR>  <TR vAlign=top bgColor=#666666><TD class="small bold colorFFFFFF" scope=col colSpan=2>端口</TD></TR>  <TR vAlign=top bgColor=#e7e7e7>    <TD class="small bold" scope=row></TD><TD class=small>20 个 RJ-45 自适应 10/100 PoE 端口 (IEEE 802.3 Type 10Base-T、IEEE 802.3u Type 100Base-TX、IEEE 802.3af PoE)<BR><BR>介质类型：Auto-MDIX<BR><BR>双工：10Base-T/100Base-TX：半双工或全双工；1000Base-T：仅全双工<BR><BR>4 个双功能定制端口<BR><BR>每个端口均可用作 RJ-45 10/100/1000 PoE 端口（IEEE 802.3 Type 10Base-T、IEEE 802.3u Type 100Base-TX、IEEE 802.3ab 1000Base-T 千兆以太网）或用作 SFP 插槽（用于 SFP 收发器）<BR><BR>1 个 RJ-45 串行控制台端口<BR><BR></TD></TR>  <TR vAlign=top bgColor=#666666><TD class="small bold colorFFFFFF" scope=col colSpan=2>物理特性</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>外形尺寸</TD><TD class=small>24.61（长）x 44.3（宽）x 4.45（高）厘米（9.69 x 17.44 x 1.75 英寸 ）(1U 高)</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>重量	</TD><TD class=small>3.27 千克（7.21 磅）</TD></TR>  <TR vAlign=top bgColor=#666666><TD class="small bold colorFFFFFF" scope=col colSpan=2>内存及处理器</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>处理器</TD><TD class=small>266 MHz 时 Freescale PowerPC 8313、32MB 闪存、128MB DDR2 SDRAM；数据包缓冲区大小：512KB 动态分配</TD></TR>  <TR vAlign=top bgColor=#666666><TD class="small bold colorFFFFFF" scope=col colSpan=2>安装</TD></TR>  <TR vAlign=top bgColor=#e7e7e7>    <TD class="small bold" scope=row></TD><TD class=small>安装在一个标准 EIA 19 英寸 Telco 机架或设备机柜中（可使用机架安装套件）；限水平表面安装、壁挂安装<BR></TD></TR>  <TR vAlign=top bgColor=#666666><TD class="small bold colorFFFFFF" scope=col colSpan=2>性能</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>100Mb 延迟</TD><TD class=small>&lt; 5.3 &micro;s（LIFO 64 字节数据包）</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>1000Mb 延迟</TD><TD class=small>&lt; 2.7 &micro;s（LIFO 64 字节数据包）</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>吞吐率</TD><TD class=small>35.7 mpps</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>交换容量</TD><TD class=small>48 Gbps</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>MAC 地址表大小</TD><TD class=small>8,000 个条目</TD></TR>  <TR vAlign=top bgColor=#666666><TD class="small bold colorFFFFFF" scope=col colSpan=2>工作环境</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>工作温度</TD><TD class=small>0&ordm;C 到 50&ordm;C（32&ordm;F 到 122&ordm;F ）</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>工作相对湿度</TD><TD class=small>40&ordm;C (104&ordm;F) 时 15% 到 95%，无凝结</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>非工作/存放温度</TD><TD class=small>-40&ordm;C 到 70&ordm;C（-40&ordm;F 到 158&ordm;F ）</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>非工作/存放相对湿度</TD><TD class=small>65&ordm;C (149&ordm;F) 时 15% 到 95%，无凝结</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>海拔</TD><TD class=small>高达 3 千米（10,000 英尺）</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>噪音</TD><TD class=small>声能：28.3 dB；声压：37.7 dB；根据 ISO 7779，DIN 45635T.19</TD></TR>  <TR vAlign=top bgColor=#666666><TD class="small bold colorFFFFFF" scope=col colSpan=2>电气特性</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>最大散热量</TD><TD class=small>223 BTU/小时（235.27 kJ/小时)</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>电压</TD><TD class=small>100 -127 / 200-240 伏交流电</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>电流</TD><TD class=small>3.3 / 1.6 安</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>待机功耗</TD><TD class=small>21.8 瓦</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>最大额定功率</TD><TD class=small>260.4 瓦</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>PoE 电源</TD><TD class=small>195 瓦</TD></TR>  <TR vAlign=top bgColor=#e7e7e7><TD class="small bold" scope=row>频率</TD><TD class=small>50/60 赫兹</TD></TR>  <TR vAlign=top bgColor=#ffffff><TD class="small bold" scope=row>备注</TD><TD class=small>待机功耗是设备没有连接端口时的实际功耗。<BR>规划完全加载 PoE（如需要）、100% 流量、全部端口插入以及使用全部模块的基础架构时，最大额定功率和最大散热量是最坏情况下的最大理论值。<BR>PoE 功率是所有 PoE 端口可用的总功率预算。<BR>待机功耗是设备没有连接端口时的实际功耗。规划完全加载 PoE、100% 流量、全部端口插入以及使用全部模块的基础架构时，最大额定功率和最大散热量是最坏情况下的最大理论值。</TD></TR>  <TR vAlign=top bgColor=#666666><TD class="small bold colorFFFFFF" scope=col colSpan=2>安全性</TD></TR>  <TR vAlign=top bgColor=#e7e7e7>    <TD class="small bold" scope=row></TD><TD class=small>cUL (CSA 22.2 No. 60950)<BR>CE 标记<BR>UL 60950-1<BR>UL 列出<BR>CAN/CSA 22.2 No. 60950<BR>EN 60825<BR>AS/NZS 60950<BR>IEC 60950-1<BR>EN 60950-1<BR></TD></TR>  <TR vAlign=top bgColor=#666666><TD class="small bold colorFFFFFF" scope=col colSpan=2>备注</TD></TR>  <TR vAlign=top bgColor=#e7e7e7>    <TD class="small bold" scope=row></TD><TD class=small>此产品使用 mini-GBIC 时需&ldquo;B&rdquo;版（产品编号以字母&ldquo;B&rdquo;或更靠后的字母结尾，例如 J4858B、J4859C）或更高版本的 mini-GBIC。<BR><BR></TD></TR></TBODY></TABLE></DIV><DIV class=topSpace><UL class=linksUnit style="TEXT-ALIGN: right"><LI>&raquo;<A   href="/other/procurve/cn/zh/network/products/switches/HP_ProCurve_2520_Switch_Series/overview.htm#tabs">返回页首</A></LI></UL></DIV><DIV class=topSpace><H3 class=headerBetaBevel><A name=models></A>所有机型的标准规格</H3></DIV><DIV><H4 class=headerGamma><A name=emission></A>辐射</H4>FCC part 15 Class A；VCCI Class A; EN 55022 Class A；CISPR 22 Class A；ICES-003（加拿大）；AS/NZS CISPR 22；IEC/EN 61000-3-2；IEC/EN 61000-3-3；IEC 61000:4-2、4-3、4-4、4-5、4-6、4-8、4-11</DIV><DIV class=topSpace><H4 class=headerGamma><A name=immunity></A>抗干扰性</H4>一般：EN 55024、CISPR 24<BR><BR>EN:EN 55024、CISPR 24<BR><BR>ESD：IEC 61000-4-2<BR><BR>辐射：IEC 61000-4-3<BR><BR>EFT/脉冲：IEC 61000-4-4<BR><BR>电涌：IEC 61000-4-5<BR><BR>导电：IEC 61000-4-6<BR><BR>电源频率磁场：IEC 61000-4-8<BR><BR>电压突降与中断：IEC 61000-4-11<BR><BR>谐波：EN 61000-3-2，IEC 61000-3-2<BR><BR>闪动：EN 61000-3-3、IEC 61000-3-3</DIV><DIV class=topSpace><H4 class=headerGamma><A name=management></A>管理</H4>HP ProCurve Manager Plus、HP ProCurve Manager、命令行界面、Web 浏览器、配置菜单、带外管理（串行 RS-232C）、IEEE 802.3 以太网 MIB、中继器 MIB、以太网接口 MIB </DIV><DIV class=topSpace><H4 class=headerGamma><A name=stadProc></A>标准与协议</H4><TABLE cellSpacing=0 cellPadding=0 summary=layout border=0>  <TBODY>  <TR>    <TD vAlign=top><H4 class=bold style="MARGIN-BOTTOM: 0px">拒绝服务保护</H4>CPU 拒绝服务保护<BR><BR><H4 class=bold style="MARGIN-BOTTOM: 0px">设备管理</H4>RFC 1591 DNS（客户端）<BR>SSHv1/SSHv2 Secure Shell<BR><BR><H4 class=bold style="MARGIN-BOTTOM: 0px">通用协议</H4>IEEE 802.1D MAC 网桥<BR>IEEE 802.1p 优先级<BR>IEEE 802.1Q VLAN<BR>IEEE 802.1s 多生成树<BR>IEEE 802.1w 生成树协议快速重配置<BR>IEEE 802.3 Type 10BASE-T<BR>IEEE 802.3ab 1000BASE-T<BR>IEEE 802.3ad 链路汇聚控制协议 (LACP)<BR>IEEE 802.3af Power over Ethernet<BR>IEEE 802.3x 流控制<BR>RFC 768 UDP<BR>RFC 783 TFTP 协议 (版本 2)<BR>RFC 792 ICMP<BR>RFC 793 TCP<BR>RFC 826 ARP<BR>RFC 854 TELNET<BR>RFC 868 时间协议<BR>RFC 951 BOOTP<BR>RFC 1350 TFTP 协议 (版本 2)<BR>RFC 1542 BOOTP 扩展<BR>RFC 2030 简单网络时间协议 (SNTP) v4<BR>RFC 2131 DHCP<BR><BR><H4 class=bold style="MARGIN-BOTTOM: 0px">IP 组播</H4>RFC 3376 IGMPv3（仅主机加入）<BR><BR><H4 class=bold style="MARGIN-BOTTOM: 0px">IPv6</H4>RFC 1981 IPv6 路径 MTU 发现<BR>RFC 2460 IPv6 规格<BR>RFC 2925 远程操作 MIB (仅限 Ping)<BR>RFC 3315 DHCPv6 (仅限客户端)<BR>RFC 3513 IPv6 寻址架构<BR>RFC 3596 DNS 扩展（用于 IPv6）<BR>RFC 4022 MIB for TCP</TD>    <TD vAlign=top><IMG height=0 alt=""       src="HP ProCurve Switch 2520 Series.files/s.gif" width=20></TD><TD vAlign=top>RFC 4113 MIB for UDP<BR>RFC 4251 SSHv6 架构<BR>RFC 4252 SSHv6 身份验证<BR>RFC 4253 SSHv6 传输层<BR>RFC 4254 SSHv6 连接<BR>RFC 4293 MIB for IP<BR>RFC 4419 SSH 密钥交换<BR>RFC 4443 ICMPv6<BR>RFC 4861 IPv6 相邻节点发现<BR>RFC 4862 IPv6 无状态地址自动配置<BR><BR><H4 class=bold style="MARGIN-BOTTOM: 0px">MIB</H4>RFC 1213 MIB II<BR>RFC 1493 网桥 MIB<BR>RFC 2021 RMONv2 MIB<BR>RFC 2613 SMON MIB<BR>RFC 2618 RADIUS 客户端 MIB<BR>RFC 2620 RADIUS 统计 MIB<BR>RFC 2665 Ethernet-Like-MIB<BR>RFC 2668 802.3 MAU MIB<BR>RFC 2674 802.1p 和 IEEE 802.1Q 网桥 MIB<BR>RFC 2737 实体 MIB（版本 2）<BR>RFC 2863 接口组 MIB<BR><BR><H4 class=bold style="MARGIN-BOTTOM: 0px">网络管理</H4>IEEE 802.1AB 链路层发现协议 (LLDP)<BR>RFC 1098 A 简单网络管理协议 (SNMP)<BR>RFC 2819 四组 RMON：1（统计信息）、2（历史记录）、3（警报）、9（事件）<BR>SNMPv1/v2c/v3<BR><BR><H4 class=bold style="MARGIN-BOTTOM: 0px">服务质量/服务级别</H4>RFC 2474 Diffserv 优先，每端口 4 个队列<BR>RFC 2475 DiffServ 架构<BR>RFC 2597 DiffServ 保证转发 (AF)<BR>RFC 2598 DiffServ 加速转发 (EF)<BR><BR><H4 class=bold style="MARGIN-BOTTOM: 0px">安全性</H4>基于 IEEE 802.1X 端口的网络访问控制<BR>RFC 1492 TACACS+<BR>RFC 2138 RADIUS 身份验证<BR>RFC 2866 RADIUS 统计<BR>SSHv2 Secure Shell</TD></TR></TBODY></TABLE></DIV><DIV class=topSpace><H4 class=headerGamma><A name=notes></A>备注</H4>此产品使用 mini-GBIC 时需&ldquo;B&rdquo;版（产品编号以字母&ldquo;B&rdquo;或更靠后的字母结尾，例如 J4858B、J4859C）或更高版本的 mini-GBIC。</DIV><DIV class=topSpace><UL class=linksUnit style="TEXT-ALIGN: right"><LI>&raquo;<A   href="/other/procurve/cn/zh/network/products/switches/HP_ProCurve_2520_Switch_Series/overview.htm#tabs">返回页首</A></LI></UL></DIV></DIV></DIV><!-- Accessories Tab Content --><DIV class=liDiv><DIV id=content4 style="DISPLAY: none"><H3 class=headerGamma>收发器</H3><UL class=linksUnit><LI>&raquo;<A   href="http://h20430.www2.hp.com/other/procurve/cn/zh/network/accessories/J9054B/accessory.htm">HP ProCurve 100-FX SFP-LC 收发器 (J9054B)</A><LI>&raquo;<A   href="http://www.procurve.com/products/accessories/J9099B/accessory.htm">HP ProCurve 100-BX-D SFP-LC 收发器 (J9099B)</A><LI>&raquo;<A   href="http://www.procurve.com/products/accessories/J9100B/accessory.htm">HP ProCurve 100-BX-U SFP-LC 收发器 (J9100B)</A></LI></UL><DIV class=topSpace><H3 class=headerGamma>Mini-GBIC</H3><UL class=linksUnit><LI>&raquo;<A   href="http://h20430.www2.hp.com/other/procurve/cn/zh/network/accessories/J4858C/accessory.htm">HP ProCurve Gigabit-SX-LC Mini-GBIC (J4858C)</A><LI>&raquo;<A   href="http://h20430.www2.hp.com/other/procurve/cn/zh/network/accessories/J4859C/accessory.htm">HP ProCurve Gigabit-LX-LC Mini-GBIC (J4859C)</A><LI>&raquo;<A   href="http://h20430.www2.hp.com/other/procurve/cn/zh/network/accessories/J4860C/accessory.htm">HP ProCurve Gigabit-LH-LC Mini-GBIC (J4860C)</A><LI>&raquo;<A   href="http://www.procurve.com/products/accessories/J9142B/accessory.htm">HP ProCurve 1000-BX-D SFP-LC Mini-GBIC (J9142B)</A><LI>&raquo;<A   href="http://www.procurve.com/products/accessories/J9143B/accessory.htm">HP ProCurve 1000-BX-U SFP-LC Mini-GBIC (J9143B)</A></LI></UL></DIV><DIV class=topSpace><H3 class=headerGamma>连接线</H3><UL class=linksUnit><LI>&raquo;<A   href="http://h71016.www7.hp.com/ctoBases.asp?oi=E9CED&amp;BEID=19701&amp;SBLID=&amp;ProductLineId=450&amp;FamilyId=1400&amp;LowBaseId=23878&amp;LowPrice=$77.00&amp;familyviewgroup=2222&amp;viewtype=Matrix">惠普以太网光缆 (JxxxxA)</A></LI></UL></DIV><DIV class=topSpace><H3 class=headerGamma>软件</H3><UL class=linksUnit><LI>&raquo;<A   href="http://h20430.www2.hp.com/other/procurve/cn/zh/network/accessories/-/accessory.htm">HP ProCurve Manager 3.0 (--)</A></LI></UL></DIV><DIV class=topSpace><UL class=linksUnit style="TEXT-ALIGN: right"><LI>&raquo;<A   href="/other/procurve/cn/zh/network/products/switches/HP_ProCurve_2520_Switch_Series/overview.htm#tabs">返回页首</A></LI></UL></DIV>');