﻿document.write('<div class="liDiv"><table cellpadding="0" cellspacing="0" border="0" width="100%" summary="layout"><tr><td valign="top"><h2 class="headerGamma">型号</h2><div class="tabularCellB width100pct lineHeight25" style="margin-top:-5px;">&raquo; <a href="#J9263A">HP ProCurve 6600-24G 交换机 (J9263A)</a></div><div class="tabularCellGrayB width100pct lineHeight25">&raquo; <a href="#J9264A">HP ProCurve 6600-24G-4XG 交换机 (J9264A)</a></div><div class="tabularCellB width100pct lineHeight25">&raquo; <a href="#J9265A">HP ProCurve 6600-24XG 交换机 (J9265A)</a></div><div class="tabularCellGrayB width100pct lineHeight25">&raquo; <a href="#J9451A">HP ProCurve 6600-48G 交换机 (J9451A)</a></div><div class="tabularCellB width100pct lineHeight25">&raquo; <a href="#J9452A">HP ProCurve 6600-48G-4XG 交换机 (J9452A)</a></div></td></tr></table><div class="topSpace"><table cellpadding="0" cellspacing="0" border="0" width="100%" summary="layout"><tr><td valign="top"><h2 class="headerGamma">所有型号的标准规格</h2><div class="tabularCellB width100pct lineHeight25" style="margin-top:-5px;">&raquo; <a href="#emission">辐射</a></div><div class="tabularCellGrayB width100pct lineHeight25">&raquo; <a href="#immunity"> 抗干扰性</a></div><div class="tabularCellB width100pct lineHeight25">&raquo; <a href="#management">管理</a></div><div class="tabularCellGrayB width100pct lineHeight25">&raquo; <a href="#stadProc">标准与协议</a></div></td></tr></table></div></div><div class="topSpace"><h3 class="headerBetaBevel"><a name="differences"></a>各型号之间的差异</h3></div><div>  <table width="100%" bgcolor="#cccccc" border="0" cellpadding="4" cellspacing="1">   <tr class="theme">  <th align="left" valign="top" class="small themebody"></th>     <th align="left" valign="top" scope="col" class="small themebody"><a name="J9263A"></a>HP ProCurve 6600-24G交换机(J9263A)<br />      <th align="left" valign="top" scope="col" class="small themebody"><a name="J9264A"></a>HP ProCurve6600-24G-4XG交换机<br />        (J9264A)</th>      <th align="left" valign="top" scope="col" class="small themebody"><a name="J9265A"></a>HP ProCurve6600-24XG交换机<br />        (J9265A)</th>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="ports"></a>端口</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">      <td class="small bold" scope="row"></td>      <td class="small">20个自适应10/100/1000端口(IEEE 802.3 Type 10Base-T、IEEE 802.3u     Type 100Base-TX、IEEE 802.3ab Type 1000Base-T)<br />        <br />介质类型：Auto-MDIX<br /> <br />        双工：10Base-T/100Base-TX：半双工或全 双工；1000Base-T：仅全双工<br /> <br />        4个双功能定制端口<br /> <br />        每个端口均可以用作RJ-45 10/100/1000端口(IEEE 802.3 Type 10Base-T、IEEE 802.3u Type100Base-TX、IEEE 802.3ab 1000Base-T千兆以太网)，或可用的mini-GBIC 插槽(用于mini-GBIC收发器)<br /><br />        1个RS-232C DB-9控制台端口<br /> <br /></td>      <td class="small">20个自适应10/100/1000端口(IEEE 802.3 Type 10Base-T, IEEE 802.3uType 100Base-TX, IEEE 802.3ab Type 1000Base-T)<br /> <br /><br />    介质类型：Auto-MDIX<br /> <br />        双工：10Base-T/100Base-TX：半双工或全双工；1000Base-T：仅全双工<br /> <br />        4个双功能定制端口<br /> <br />        每个端口均可以用作RJ-45 10/100/1000端口(IEEE 802.3 Type 10Base-T、IEEE 802.3u Type100Base-TX、IEEE 802.3ab 1000Base-T千兆以太网)，或可用的mini-GBIC 插槽(用于mini-GBIC收发器)<br /><br />        4个SFP+ 10-GbE端口<br /> <br />        双工：仅全双工<br /> <br />        1个RS-232C DB-9控制台端口<br /> <br /></td>      <td class="small">24个SFP+ 10-GbE端口 <br /><br />      双工：仅全双工<br /> <br />        1个RJ-45串行控制台端口<br /> <br /></td>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="powerSup"></a>电源</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">      <td class="small bold" scope="row"></td>      <td class="small">2个可用的电源插槽<br /> <br />        包括：1个J9269A HP ProCurve 6600交换机电源<br /> <br /></td>      <td class="small">2个可用的电源插槽<br /> <br />        包括：1个J9269A HP ProCurve 6600交换机电源<br /> <br /></td>      <td class="small">2个可用的电源插槽<br /> <br />        包括：1个J9269A HP ProCurve 6600交换机电源<br /> <br /></td>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="fanTray"></a>风扇托盘</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row"></td>      <td class="small">包括1个J9271A</td> <td cla"small">包括1个J9271A</td>      <td class="small">包括1个J9271A</td>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="physChar"></a>物理特性</td> </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row">外形尺寸(长 x 宽 x 高)</td>      <td class="small">54.61 x 44.25 x 4.32厘米(21.5 x 17.42 x 1.7英寸) (1U高)</td>      <td class="small">54.61 x 44.25 x 4.32厘米(21.5 x 17.42 x 1.7英寸) (1U高)</td>   <td class="small">64.14 x 44.25 x 4.32 厘米(25.25 x 17.42 x 1.7 英寸)<br/>(1U高)</td>    </tr>    <tr valign="top" bgcolor="#ffffff">       <td class="small bold" scope="row">重量</td>      <td class="small">7.58千克(16.7磅)</td>      <td class="small">7.8千克(17.2磅)</td>      <td class="small">8.94千克(19.7磅)</td>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="memory"></a>内存和处理器</td>  </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row"></td>      <td class="small">666 MHz时Freescale PowerPC 8540、4MB 闪存、256MB compact flash、256MBDDR SDRAM；数据包缓冲区大小：共18MB QDR SDRAM(用于所有1-GbE端口)</td>      <td class="small">666 MHz时Freescale PowerPC 8540、4M闪存、256MB compact flash、256MBDDR SDRAM；数据包缓冲区大小：共36MB QDR SDRAM (18MB用于所有1-GbE端口；18MB用于所有10-GbE端口)</td>      <td class="small">666 MHz时Freescale PowerPC 8540、4MB 闪存、1GB compact flash、256MBDDR SDRAM；数据包缓冲区大小：共108MB QDR SDRAM(用于所有10-GbE端口)</td>  </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="mount"></a>安装</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row"></td>      <td class="small">Telco机架：安装在一个标准EIA 19英寸双柱Telco机架或设备机柜中；限水平表面安装。机架套件：在HP <div></div>        10000系列4柱机架内安装时，需要机架导轨。<br /></td>      <td class="small">Telco机架：安装在一个标准EIA 19英寸双柱Telco机架或设备机柜中；限水平表面安装。机架套件：在HP10000系列4柱机架内安装时，需要机架导轨。<br /></td>      <td class="small">Telco机架：安装在一个标准EIA 19英寸双柱Telco机架或设备机柜中；限水平表面安装。机架套件：在HP10000系列4柱机架内安装时，需要机架导轨。<br /></td>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="perf"></a>性能</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row">1000 Mb 延迟</td>      <td class="small">小于 3.7 &#181;s (FIFO 64-字节数据包)</td>      <td class="small">小于 3.7 &#181;s (FIFO 64-字节数据包)</td>      <td class="small">小于 3.7 &#181;s (FIFO 64-字节数据包)</td>    </tr>    <tr valign="top" bgcolor="#ffffff">       <td class="small bold" scope="row">10 Gbps 延迟</td>      <td class="small">小于 2.1 &#181;s (FIFO 64-字节数据包)</td>      <td class="small">小于 2.1 &#181;s (FIFO 64-字节数据包)</td>      <td class="small">小于 2.1 &#181;s (FIFO 64-字节数据包)</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row">吞吐率</td>      <td class="small">35.7 Mpps</td>      <td class="small">75.7 Mpps</td>      <td class="small">240.2 Mpps</td>    </tr>    <tr valign="top" bgcolor="#ffffff">       <td class="small bold" scope="row">路由/交换容量</td>      <td class="small">48 Gbps</td>      <td class="small">101.8 Gbps</td>      <td class="small">322.8 Gbps</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row">交换机矩阵速率</td>      <td class="small">48 Gbps</td>      <td class="small">105.6 Gbps</td>      <td class="small">345.6 Gbps</td>    </tr>    <tr valign="top" bgcolor="#ffffff">       <td class="small bold" scope="row">路由表大小</td>      <td class="small">10000 个条目</td>      <td class="small">10000 个条目</td>      <td class="small">10000 个条目</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row">MAC地址表大小</td>      <td class="small">64000 个条目</td>      <td class="small">64000 个条目</td>      <td class="small">64000 个条目</td>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="env"></a>环境</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row">工作温度</td>      <td class="small">5&deg;C到40&deg;C (41&deg;F到104&deg;F) </td>      <td class="small">5&deg;C到40&deg;C (41&deg;F到104&deg;F) </td>      <td class="small">0&deg;C到40&deg;C (32&deg;F到104&deg;F) </td>    </tr>    <tr valign="top" bgcolor="#ffffff">       <td class="small bold" scope="row">工作相对湿度</td>      <td class="small">40&deg;C (104&deg;F)时15%到80%，无凝结 </td>      <td class="small">40&deg;C (104&deg;F)时15%到80%，无凝结 </td>      <td class="small">40&deg;C (104&deg;F)时15%到80%，无凝结 </td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row">非工作/存放温度</td>      <td class="small">-40&deg;C到70&deg;C (-40&deg;F到158&deg;F)</td>      <td class="small">-40&deg;C到70&deg;C (-40&deg;F到158&deg;F)</td>      <td class="small">-40&deg;C到70&deg;C (-40&deg;F到158&deg;F)</td>    </tr>    <tr valign="top" bgcolor="#ffffff">       <td class="small bold" scope="row">非工作/存放相对湿度</td>      <td class="small">70&deg;C (158&deg;F)时15%到90%，无凝结</td>      <td class="small">65&deg;C (149&deg;F)时15%到90%，无凝结</td>      <td class="small">65&deg;C (149&deg;F)时15%到90%，无凝结</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row">高度</td>      <td class="small">3千米(10000英尺)</td>      <td class="small">3千米(10000英尺)</td>      <td class="small">3千米(10000英尺)</td>    </tr>    <tr valign="top" bgcolor="#ffffff">       <td class="small bold" scope="row">噪音</td>      <td class="small">功耗：71dB；声压：62.3 dB ISO 7779、ISO 9296</td>      <td class="small">功耗：68dB；声压：59.5 dB ISO 7779、ISO 9296</td>      <td class="small">功耗：72dB；声压：61.8 dB ISO 7779、ISO 9296</td>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="elecChar"></a>电气特性</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td bgcolor="#FFFFFF" class="small bold" scope="row">&nbsp;</td>      <td bgcolor="#FFFFFF" class="small">&nbsp;</td>      <td bgcolor="#FFFFFF" class="small">荣获 Miercom 绿色认证大奖</td>      <td bgcolor="#FFFFFF" class="small">荣获 Miercom 绿色认证大奖</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row">说明</td>      <td class="small">该交换机可自动调节的电压范围在100 — 120和200 — 240伏之间，频率为50或60赫兹</td>      <td class="small">该交换机可自动调节的电压范围在100 —120和200 — 240伏之间，频率为50或60赫兹</td>      <td class="small">该交换机可自动调节的电压范围在100 — 120和200 — 240伏之间，频率为50或60赫兹</td>    </tr>    <tr valign="top" bgcolor="#ffffff">       <td class="small bold" scope="row">最大散热量</td>      <td class="small">425 BTU/小时(448.38 kJ/小时)</td>      <td class="small">587 BTU/小时(619.29 kJ/小时)</td>      <td class="small">1268 BTU/小时(1337.74 kJ/小时)</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row">电压</td>      <td class="small">100 — 120伏交流电/200 — 240伏交流电</td>      <td class="small">100 — 120伏交流电/200 — 240伏交流电</td>      <td class="small">100 — 120伏交流电/200 — 240伏交流电</td>    </tr>    <tr valign="top" bgcolor="#ffffff">       <td class="small bold" scope="row">待机功耗</td>      <td class="small">92.5 瓦</td>      <td class="small">127.4 瓦</td>      <td class="small">309.8 瓦</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row">最大额定功率</td>      <td class="small">124.6 瓦</td>      <td class="small">172.1 瓦</td>      <td class="small">371.6 瓦</td>    </tr>    <tr valign="top" bgcolor="#ffffff">       <td class="small bold" scope="row">频率</td>      <td class="small">50 / 60 赫兹</td>      <td class="small">50 / 60 赫兹</td>      <td class="small">50 / 60 赫兹</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row">备注</td>      <td class="small">待机功耗指基本系统没有流量时的功耗。规划完全加载PoE (如需要)、100%流量、全部端口插入以及使用全部模块的基础架构时，最大额定功率和最大散热量是最坏情况下的最大理论值。</td>      <td class="small">待机功耗指基本系统没有流量时的功耗。规划完全加载PoE (如需要)、100%流量、全部端口插入以及使用全部模块的基础架构时，最大额定功率和最大散热量是最坏情况下的最大理论值。</td>      <td class="small">待机功耗指基本系统没有流量时的功耗。规划完全加载PoE (如需要)、100%流量、全部端口插入以及使用全部模块的基础架构时，最大额定功率和最大散热量是最坏情况下的最大理论值。</td>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="safety"></a>安全性</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row"></td>      <td class="small">CSA 22.2 No. 60950<br />        EN 60950/IEC 60950<br />        UL 60950<br /></td>      <td class="small">CSA 22.2 No. 60950<br />        EN 60950/IEC 60950<br />        UL 60950<br /></td>      <td class="small">CSA 22.2 No. 60950<br />        EN 60950/IEC 60950<br />        UL 60950<br /></td>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="notes"></a>备注</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row"></td>      <td class="small">此产品使用mini-GBIC时，需“B”版(产品编号以字母“B”或更靠后的字母结尾，例如J4858B、J4859C)或更高版本的mini-GBIC。3500yl系列交换机不支持Gigabit1000Base-T mini-GBIC (J8177B)。<br /> <br /></td>      <td class="small">此产品使用mini-GBIC时，需“B”版(产品编号以字母“B”或更靠后的字母结尾，例如J4858B、J4859C)或更高版本的mini-GBIC。3500yl系列交换机不支持Gigabit1000Base-T mini-GBIC (J8177B)。<br /> <br /></td>      <td class="small">此产品使用mini-GBIC时，需“B”版(产品编号以字母“B”或更靠后的字母结尾，例如J4858B、J4859C)或更高版本的mini-GBIC。3500yl系列交换机不支持Gigabit1000Base-T mini-GBIC (J8177B)。<br /> <br /></td>    </tr>  </table></div><div class="topSpace"><ul class="linksUnit" style="text-align: right;"><li>&raquo;<a href="#tabs">返回页首</a></li></ul></div><div class="topSpace">  <table width="100%" bgcolor="#cccccc" border="0" cellpadding="4" cellspacing="1">    <tr class="theme">       <th align="left" valign="top" class="small themebody"></th>      <th align="left" valign="top" scope="col" class="small themebody"><a name="J9451A"></a>HP ProCurve6600-48G 交换机<br />        (J9451A)</th>      <th align="left" valign="top" scope="col" class="small themebody"><a name="J9452A"></a>HP ProCurve6600-48G-4XG 交换机<br />        (J9452A)</th>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="6">端口</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row"></td>      <td class="small">44个自适应10/100/1000端口(IEEE 802.3 Type 10Base-T, IEEE 802.3uType 100Base-TX, IEEE 802.3ab Type 1000Base-T)<br /> <br />        介质类型：Auto-MDIX<br /> <br />        双工：10Base-T/100Base-TX：半双工或全双工；1000Base-T：仅全双工<br /> <br />        4个双功能定制端口<br /> <br />        每个端口均可以用作(IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE802.3ab 1000Base-T 千兆以太网)，或可用的mini-GBIC插槽(用于mini-GBIC收发器)<br /> <br />        1个RJ-45串行控制台端口<br /> <br /></td>      <td class="small">48个RJ-45自适应10/100/1000端口(IEEE 802.3 Type 10Base-T, IEEE802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)<br /> <br />        介质类型：Auto-MDIX<br /> <br />        双工：10Base-T/100Base-TX：半双工或全双工；1000Base-T：仅全双工<br /> <br />        4个SFP+ 10-GbE端口<br /> <br />        双工：仅全双工<br /> <br />        1个RJ-45控制台端口<br /> <br /></td>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="6">电源</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row"></td>      <td class="small">2个可用的电源插槽<br /> <br />        包括：1个J9269A HP ProCurve 6600交换机电源<br /> <br /></td>      <td class="small">2个可用的电源插槽<br /> <br />        包括：1个J9269A HP ProCurve 6600交换机电源<br /> <br /></td>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="6">风扇托盘</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row"></td>      <td class="small">包括1个J9271A</td>      <td class="small">包括1个J9271A</td>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="6">物理特性</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row">外形尺寸(长 x 宽 x 高)</td>      <td class="small">64.14 x 44.25 x 4.32厘米(25.25 x 17.42 x 1.7英寸) (1U高)</td><td class="small">64.14 x 44.25 x 4.32厘米(25.25 x 17.42 x 1.7英寸)(1U高)</td>    </tr>    <tr valign="top" bgcolor="#ffffff">      <td class="small bold" scope="row">重量</td>      <td class="small">8.62千克(19磅)</td>      <td class="small">8.62千克(19磅)</td>    </tr>    <tr valign="top" bgcolor="#666666">      <td class="small bold colorFFFFFF" scope="col" colspan="6">内存和处理器</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">     <td class="small bold" scope="row"></td>      <td class="small">66 MHz时Freescale PowerPC 8540、4MB闪存、1GB compact flash、256MBDDR SDRAM； 数据包缓冲区大小：共36MB QDR SDRAM(用于所有1-GbE端口)</td>      <td class="small">666 MHz时Frescale PowerPC 8540、4MB闪存、1GB compact flash、256MBDDR SDRAM；数据包缓冲区大小：共72MB QDR SDRAM (36MB用于所有1-GbE端口；36MB用于所有10-GbE端口)</td>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="6">安装</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row"></td>      <td class="small">安装在一个标准EIA 19英寸双点Telco机架或设备机柜中(包含硬件)；限水平表面安装<br /></td>      <td class="small">安装在一个标准EIA 19英寸双点Telco机架或设备机柜中(包含硬件)；限水平表面安装<br /></td>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="6">性能</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">      <td class="small bold" scope="row">1000 Mb 延迟</td>      <td class="small">小于 3.7 &#181;s (FIFO 64字节数据包)</td>      <td class="small">小于 3.7 &#181;s (FIFO 64字节数据包)</td>    </tr>    <tr valign="top" bgcolor="#ffffff">       <td class="small bold" scope="row">10 Gbps 延迟</td>      <td class="small">小于 2.1 &#181;s (FIFO 64字节数据包)</td>      <td class="small">小于 2.1 &#181;s (FIFO 64字节数据包)</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row">吞吐率</td>      <td class="small">71.4 Mpps</td>      <td class="small">130.9 Mpps</td>    </tr>    <tr valign="top" bgcolor="#ffffff">       <td class="small bold" scope="row">路由/交换容量</td>      <td class="small">96 Gbps</td>      <td class="small">176 Gbps</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row">交换机矩阵速率</td>      <td class="small">96 Gbps</td>      <td class="small">176 Gbps</td>    </tr>    <tr valign="top" bgcolor="#ffffff">       <td class="small bold" scope="row">路由表大小</td>      <td class="small">10000 个条目</td>      <td class="small">10000 个条目</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">      <td class="small bold" scope="row">MAC地址表大小</td>      <td class="small">64000 个条目</td>      <td class="small">64000 个条目</td>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="6">环境</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row">工作温度</td>      <td class="small">5&deg;C到40&deg;C (41&deg;F到104&deg;F) </td>      <td class="small">5&deg;C到40&deg;C (41&deg;F到104&deg;F) </td>    </tr>    <tr valign="top" bgcolor="#ffffff">       <td class="small bold" scope="row">工作相对湿度</td>      <td class="small">40&deg;C (104&deg;F)时15%到80%，无凝结 </td>      <td class="small">40&deg;C (104&deg;F)时15%到80%，无凝结 </td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row">非工作/存放温度</td>      <td class="small">-40&deg;C到70&deg;C (-40&deg;F到158&deg;F)</td>      <td class="small">-40&deg;C到70&deg;C (-40&deg;F到158&deg;F)</td>    </tr>    <tr valign="top" bgcolor="#ffffff">       <td class="small bold" scope="row">非工作/存放相对湿度</td>      <td class="small">70&deg;C (158&deg;F)时15%到90%，无凝结 </td>      <td class="small">70&deg;C (158&deg;F)时15%到90%，无凝结 </td>    </tr>   <tr valign="top" bgcolor="#e7e7e7">    <td class="small bold" scope="row">高度</td>    <td class="small">3千米(10000英尺)</td>    <td class="small">3千米(10000英尺)</td>    </tr>  <tr valign="top" bgcolor="#e7e7e7">       <td bgcolor="#FFFFFF" class="small bold" scope="row">噪音</td>      <td bgcolor="#FFFFFF" class="small">&nbsp;</td>      <td bgcolor="#FFFFFF" class="small">ISO 7779, ISO 9296</td>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="6">电气特性</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td bordercolor="#FFFFFF" bgcolor="#FFFFFF" class="small bold" scope="row">说明</td>      <td bordercolor="#FFFFFF" bgcolor="#FFFFFF" class="small">该交换机可自动调节的电压范围在100—120和200 — 240伏之间，频率为50或60赫兹</td>      <td bordercolor="#FFFFFF" bgcolor="#FFFFFF" class="small">该交换机可自动调节的电压范围在100—120和200 — 240伏之间，频率为50或60赫兹</td>    </tr>    <tr valign="top" bgcolor="#ffffff">       <td bgcolor="#E7E7E7" class="small bold" scope="row">电压</td>      <td bgcolor="#E7E7E7" class="small">100 — 120伏交流电/200 — 240伏交流电</td>      <td bgcolor="#E7E7E7" class="small">100 — 120伏交流电/200 — 240伏交流电</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">      <td bgcolor="#FFFFFF" class="small bold" scope="row">频率</td>      <td bgcolor="#FFFFFF" class="small">50 / 60 赫兹</td>      <td bgcolor="#FFFFFF" class="small">50 / 60 赫兹</td>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="6">安全性</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row"></td>      <td class="small">CSA 22.2 No. 60950<br />        EN 60950/IEC 60950<br />        UL 60950<br /></td>      <td class="small">CSA 22.2 No. 60950<br />        EN 60950/IEC 60950<br />        UL 60950<br /></td>    </tr>    <tr valign="top" bgcolor="#666666">       <td class="small bold colorFFFFFF" scope="col" colspan="6">备注</td>    </tr>    <tr valign="top" bgcolor="#e7e7e7">       <td class="small bold" scope="row"></td>      <td class="small">此产品使用mini-GBIC时，需“B”版(产品编号以字母“B”或更靠后的字母结尾，例如J4858B、J4859C)或更高版本的mini-GBIC。3500yl系列交换机不支持Gigabit1000Base-T mini-GBIC (J8177B)。<br /> <br /></td>      <td class="small">此产品使用mini-GBIC时，需“B”版(产品编号以字母“B”或更靠后的字母结尾，例如J4858B、J4859C)或更高版本的mini-GBIC。3500yl系列交换机不支持Gigabit1000Base-T mini-GBIC (J8177B)。<br /> <br /></td>    </tr>  </table></div><div class="topSpace"><ul class="linksUnit" style="text-align: right;"><li>&raquo;<a href="#tabs">返回页首</a></li></ul></div><div class="topSpace"><h3 class="headerBetaBevel"><a name="models"></a>所有型号的标准规格</h3></div><div><h4 class="headerGamma"><a name="emission"></a>辐射</h4>FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A</div><div class="topSpace"><h4 class="headerGamma"><a name="immunity"></a>抗干扰性</h4>EN: EN 55024, CISPR 24<br /><br />ESD: IEC 61000-4-2<br /><br />辐射: IEC 61000-4-3<br /><br />EFT/脉冲: IEC 61000-4-4<br /><br />电涌: IEC 61000-4-5<br /><br />导电: IEC 61000-4-6<br /><br />电源频率磁场: IEC 61000-4-8<br /><br />电压突降与中断: IEC 61000-4-11<br /><br />谐波: EN 61000-3-2, IEC 61000-3-2<br /><br />闪动: EN 61000-3-3, IEC 61000-3-3</div><div class="topSpace"><h4 class="headerGamma"><a name="management"></a>管理</h4>HP ProCurve Manager Plus；HP ProCurve Manager(附带)；命令行界面；Web浏览器；配置菜单；带外管理(串行RS-232C)</div><div class="topSpace"><h4 class="headerGamma"><a name="stadProc"></a>标准与协议</h4><table cellpadding="0" cellspacing="0" border="0" summary="layout"><tr><td valign="top"><h4 class="bold" style="margin-bottom: 0px;">设备管理</h4>RFC 1591 DNS (客户端)<br />HTML and telnet 管理<br /><br /><h4 class="bold" style="margin-bottom: 0px;">通用协议</h4>        IEEE 802.1ad Q-in-Q (Premium许可)<br />        IEEE 802.1D MAC 网桥<br />IEEE 802.1p 优先级<br />       IEEE 802.1Q VLAN<br />        IEEE 802.1s 多生成树<br />IEEE 802.1v VLAN 分类(按协议和端口)<br />IEEE 802.1w 生成树的快速重新配置<br />IEEE 802.3ad 链路汇聚控制协议(LACP)<br />IEEE 802.3x 流控制<br />RFC 768 UDP<br />RFC 783 TFTP 协议(修订版2)<br />RFC 792 ICMP<br />RFC 793 TCP<br />UDLD (单向链路检测)<br />RFC 826 ARP<br />RFC 854 TELNET<br />RFC 868 时间协议<br />RFC 951 BOOTP<br />RFC 1058 RIPv1<br />RFC 1350 TFTP 协议(修订版2)<br />RFC 1519 CIDR<br />RFC 1542 BOOTP 扩展<br />        RFC 2030 简单网络时间协议(SNTP) v4<br />        RFC 2131 DHCP<br />RFC 2453 RIPv2<br />        RFC 2548 (仅MS-RAS-Vendor)<br />      RFC 3046 DHCP 中继代理信息选项<br />       RFC 3576 扩展 RADIUS (仅CoA)<br />        RFC 3768 VRRP (Premium 许可)<br />RFC 4675 RADIUS VLAN与优先级<br /><br /><h4 class="bold" style="margin-bottom: 0px;">IP 组播</h4>RFC 3376 IGMPv3 (仅主机加入)<br />RFC 3973草案2 PIM密集模式(Premium许可)<br />RFC 4601草案10 PIM稀疏模式(Premium许可)<br /><br /><h4 class="bold" style="margin-bottom: 0px;">IPv6</h4>RFC 1981 IPv6 路径MTU发现<br />RFC 2460 IPv6 规格<br />       RFC 2461 IPv6 相邻节点发现<br>        RFC 2462 IPv6 无状态地址自动配置<br/>        RFC 2463 ICMPv6<br/>        RFC 2710 IPv6 组播监听者发现(MLD)<br/>        RFC 2925 远程操作MIB (仅Ping)<br/>        RFC 3019 MLDv1 MIB<br>RFC 315 DHCPv6 (仅客户端)<br>RFC 3513 IPv6寻址架构</td><td valign="top"><img src="http://welcome.hp-ww.com/img/s.gif" width="20" height="0" alt="" /></td><td valign="top">RFC 3596 DNS IPv6 扩展<br/>  RFC 3810 MLDv2 (仅主机加入)<br/>RFC 4022 MIB for TCP<br/>RFC 4113 MIB for UDP<br/>  RFC 4251 SSHv6 架构<br/>  RFC 4252 SSHv6 身份验证<br/>  RFC 4253 SSHv6 传输层<br/>  RFC 4254 SSHv6 连接<br/>  RFC 4293 MIB for IP<br/>  RFC 4419 SSH 密钥交换<br/>  RFC 4541 IGMP与MLD 侦听交换机<br />  <br />        <h4 class="bold" style="margin-bottom: 0px;">MIB</h4>        RFC 1213 MIB II<br />RFC 1493 网桥 MIB<br />RFC 1724 RIPv2 MIB<br />RFC 1850 OSPFv2 MIB<br />RFC 2021 RMONv2 MIB<br />RFC 2096 IP 转发表 MIB<br />RFC 2613 SMON MIB<br />RFC 2618 客户端 MIB<br />  RFC 2620 RADIUS 统计 MIB<br />  RFC 2665 Ethernet-Like-MIB<br />RFC 2668 802.3 MAU MIB<br />RFC 2674 802.1p和IEEE 802.1Q网桥MIB<br />RFC 2737 实体MIB (版本2)<br />RFC 2787 VRRP MIB<br />RFC 2863 接口组 MIB<br />RFC 2925 Ping MIB<br /><br /><h4 class="bold" style="margin-bottom: 0px;">网络管理</h4>IEEE 802.1AB 链路层发现协议(LLDP)<br />RFC 2819 四组RMON：1 (统计信息)、2 (历史记录)、3 (警报)、9 (事件)<br />RFC 3176 sFlow<br />ANSI/TIA-1057 介质终端发现 (LLDP-MED)<br />NMPv1/v2c/v3<br />XRMON<br /><br /><h4 class="bold" style="margin-bottom: 0px;">OSPF</h4>RFC 2328 OSPFv2 (Premium许可)<br />RFC 3101 OSPF NSSA<br /><br /><h4 class="bold" style="margin-bottom: 0px;">QoS/Cos</h4>RFC 2474 DiffServ优先，包括8个队列/端口<br />  RFC 2597 DiffServ保证转发(AF)<br />RFC 2598 DiffServ加速转发(EF)<br /><br /><h4 class="bold" style="margin-bottom: 0px;">安全性</h4>基于IEEE 802.1X端口的网络访问控制<br />RFC 1492 TACACS+<br />RFC 2865 RADIUS (仅客户端)<br />RFC 2866 RADIUS 统计<br />加密套接字协议层 (SSL)<br />SSHv2 Secure Shell</td></tr></table></div><div class="topSpace"><h4 class="headerGamma"><a name="notes2"></a>备注</h4>6600 系列交换机不支持J8177B 千兆1000Base-T mini-GBIC 应用</div><div class="topSpace"><ul class="linksUnit" style="text-align: right;"><li>&raquo;<a href="#tabs">返回页首</a></li></ul></div>');
